Handheld Thermometer HR-1550K/ HR-1550E

Measurement Range:K -200 to 1370°C / E -200 to 800°C

ホールド
HOLD
The thermometer stops measurement
by the HOLD key and holds the present readings.
オートパワーオフ
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
分解能切替
Resolution change
Press the [RESO] key to change the resolution of readings.
PVホールド
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
バックライト
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
画像
Memory function
Stores readings at user-selected time intervals.
User specified time interval and the remaining amount of memory are displayed on the sub-display.

(Temperature probes not included)

Download catalog

Specifications

ModelHR-1550
DisplayLCD
Waterproof specifications-
Input connectorANP
Input typeThermocouple Input: Type E, K
Channel1ch
Signal source resistanceMAX.1k ohm
Measurement Range1°C ResolutionE-200 to 800°C
K-200 to 1370°C
0.1°C ResolutionE

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

K

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

Measurement Accuracy1°C Resolution0°C to± (0.1% of reading +1°C)
to 0°C± (0.5% of reading +1°C)
0.1°C Resolution0°C to± (0.05% of reading + 0.2°C)
to 0°C± (0.15% of reading + 0.2°C)
Reference junction compensation accuracy±0.2°C at 25°C±10°C
Temperature Coefficient*1

±0.02×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.5°C is added at room temp. of 0°C or 50°C)

Operation Environment

0 to 50°C, 0 to 80%RH (Non condensing)

Storage Environment

-20 to 50°C, 0 to 85%RH (Non condensing)

Battery lifeapprox.550h
Power supply(Dry battery)4 AA Alkaline batteries
Power supply(AC power) optionavailable
Sampling rateapprox.200ms
LinearlizerDigital Linearizer method (Compliant with JIS C1602-2015)
Dimensions(mm)approx. 82(w)×166(H)×36(D)  [Protruded parts excluded]
Weightapprox. 350g [Include Batteries]
Supplied accessoriesManual,Test report,Soft case,
Hand strap,4 AA Alkaline batteries
Optional accessoriesCommunication cable, Software(AMS-350)
Memory functionTABLE1
Compatible standards

EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)

RoHS:IEC EN 63000:2018

*1 Only when the temp. exceeds 25°C±10°C

※ Details of typeJ,T,R(option)

TABLE1 Memory function

Time intervalsecond:1, 5, 10, 30 minutes:1, 5, 10, 30, 60 and manual memory
Memory capacity19999data


Software

Download data

画像

Data stored in memory can be transmitted to a personal computer through USB interface and can converted into CSV files.

Operational environment OS software(AMS-100)

OSWindows® 8.1、Windows® 10
System32bit / 64bit


* All PCs under the recommended environment are not guaranteed to work successfully with AMS-950.
* AMS-950 can be used only by the user that has a system administrative right (Administrator)
* Microsoft® Windows® 8.1, Windows® 10, and Excel® are registered trademarks of Microsoft Corporation in the United States and other countries.

Supplied accessories

試験成績書

Test report

ソフトケース 形名:SCHD

Soft case model:SCHR2

ハンドストラップ

Hand strap

Optional accessories

画像

AC-Adaptor

model : AD-115-500-HR-R (for AC115V)
model : AD-220-500-HR-R (for AC220V)
for HR-1300,HR-1350,HR-1301,HR-1351,HR-1500,HR-1550
* Not CE-approval

画像

Soft case

model:SCHR

About repair

This product is available for repair. Please ask our dealer.