Handheld Thermometer HR-1300K / HR-1300E

Measurement Range:K -200 to 1370°C / E -200 to 800°C

ホールド
HOLD
The thermometer stops measurement
by the HOLD key and holds the present readings.
オートパワーオフ
Auto power-off
The thermometer will turn the power off automatically after 5minutes.
分解能切替
Resolution change
Press the [RESO] key to change the resolution of readings.
PVホールド
P/V Hold
The peak (Max.) value and the valley (Min.) value can be displayed by the P/V HOLD key on the sub-display.
バックライト
Backlight
The backlight will operate by the Backlight key and the LCD display will be visible even in a dark place.
画像
Calibration
The displayed value can be adjusted the CAL SET key.
画像
Alarm output
The thermometer gives an alarm when readings go beyond the high or low limits.

(Temperature probes not included)

Download catalog

Specifications

ModelHR-1300
DisplayLCD
Waterproof specifications-
Input connectorASP
Input typeThermocouple Input: Type E, K
Channel1ch
Signal source resistanceMAX.1k ohm
Measurement Range1°C ResolutionE-200 to 800°C
K-200 to 1370°C
0.1°C ResolutionE

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

K

-104.9 to 504.9°C

(Switches automatically to 1°C resolution range when messured temperatures fall outside the 0.1°C resolution range.)

Measurement Accuracy1°C Resolution0°C to± (0.1% of reading +1°C)
to 0°C± (0.5% of reading +1°C)
0.1°C Resolution0°C to± (0.05% of reading + 0.2°C)
to 0°C± (0.15% of reading + 0.2°C)
Reference junction compensation accuracy±0.2°C at 25°C±10°C
Temperature Coefficient*1

±0.02×Δt°C (Add the value obtained by multiplying the excess temp.Δt[°C] by a coefficient to the total accuracy. e.g. ±0.3°C is added at room temp. of 0°C or 50°C)

Operation Environment

0 to 50°C, 0 to 80%RH (Non condensing)

Storage Environment

-20 to 50°C, 0 to 85%RH (Non condensing)

Battery lifeapprox.600h
Power supply(Dry battery)4 AA Alkaline batteries
Power supply(AC power) optionavailable
Sampling rateapprox.200ms
LinearlizerDigital Linearizer method (Compliant with JIS C1602-2015)
Dimensions(mm)approx. 82(w)×166(H)×36(D)  [Protruded parts excluded]
Weightapprox. 350g [Include Batteries]
Supplied accessoriesManual,Test report,Soft case,
Hand strap,4 AA Alkaline batteries
Optional accessoriesAlarm output cable
Alarm outputTABLE1
Compatible standards

EMC:EN61326-1:2013, EN 61326-2-1:2013 classA Table2( Industrial)

RoHS:IEC EN 63000:2018

*1 Only when the temp. exceeds 25°C±10°C

※ Details of typeJ,T,R(option)

Table1 Alarm output

Output PatternUpper LimitLower Limit
More than upper limitCloseOpen
Between upper and lower limitOpenOpen
Less than lower limitOpenClose
Alarm output cableANGHA-1.5(accessory)

※ The alarm output uses a photo MOS relay. ON resistance(internal protection resistance 400Ω, photo MOS relay ON resistance 50Ω) Drive voltage MAX.25V

Supplied accessories

試験成績書

Test report

Soft case model:SCHR2

ハンドストラップ

Hand strap

Alarm output cable
model:ALMHA-1.5

Optional accessories

画像

AC-Adaptor

model : AD-115-500-HR-R (for AC115V)
model : AD-220-500-HR-R (for AC220V)
for HR-1300,HR-1350,HR-1301,HR-1351,HR-1500,HR-1550
* Not CE-approval

画像

Soft case

model : SCHR

About repair

This product is available for repair. Please ask our dealer.