Described below are procedures for ensuring the accuracy, durability, and correct use of your Anritsu Meter temperature measuring product.
The thermocouples used in Anritsu Meter products comply with the Class 2 accuracy standards specified within the Japanese Industrial Standard JIS C1602-1995.
However, since probes structure and other factors can affect the accuracy of specific temperature measuring probes, please refer to the pertinent pages for information on the precision of specific probes.
| Type | Measuring Temperature | Accuracy |
| K | 333 to 1200°C | ±0.75% of measured temperature |
| -40 to 333°C | ±2.5°C | |
| E | 333 to 900°C | ±0.75% of measured temperature |
| -40 to 333°C | ±2.5°C |
| specification indicated in catalog | At 100°C Surface | At 100°C |
| Test temperature | 100°C | 100°C |
| Probe application | Stationary surface probes | Internal probes |
| Moving / rotating surface probes | Air / gas probes | |
| Test method | Measurement of stationary metal surface temperatures | Measurement of boiling water by immersion Measurement of steam temperatures |
The accuracy of surface probes can vary significantly depending on measuring conditions, measurement target, and the nature of the contact between the probe and measurement target.
When using a probe, make sure the sensor head correctly contacts target surface.

The response time given for our temperature measuring probes is the time required to detect 99% of the true value.
| Probe application | Test method |
| Stationary Surface Probes | Measurement of stationary metal surface temperatures |
| Moving / Rotating Surface Probes | |
| Internal Probes | Measurement of boiling water by immersion |
| Air / Gas Probes | Measurement of steam temperatures |
| EX) Stationary Surface Probes : N-213K | EX) Internal Probes : BS-21K |
![]() |
![]() |
| For surface temperature | For internal temperature |
The probe product pages use the following symbols to indicate probe durability.
Note that probe durability can vary significantly depending on actual conditions of use.
| Durability rank | Stationary Surface Temperature probes | Moving / Rotating Surface Temperature probes | Liquid or Gas Temperature probes |
| A | More than 50,000 contacts | More than 1500 hours continuously | Long lived(indefinable) |
| B | More than 10,000 contacts | More than 1000 hours continuously | More than 1 year |
| C | More than 5,000 contacts | More than 500 hours continuously | More than 6 months |
| D | Less than 5,000 contacts | Less than 500 hours continuously | Less than 6 months |
| S | Can not evaluate because of special-application | ||